TX4000 – Cable Fault Locator

TX4000  Cable Fault Locator

Ref: 4403900

• Auto Fault Location
• Rugged Palm-Top design
• Weighs less than 350g (12oz)
• 11 Measurement Ranges up to 4000m(4km)
• 25, 50, 75 & 100ohm Selectable Cable Impedance
• User Variable Gain Control
• Built in Tone Generator for Pair Tracing and Identification
• Suitable for testing all Communication and Power Cables
• Environmental Protection IP54
• CE Approved
• Soft bag & Test Leads

Where to buy



The TX4000 is a hand held Time Domain Reflectometer with 11 range scales covering the range 0-4000 meters, with a 7 mater first range scale and a 0.5 meter dead zone near and far end faults are clearly displayed on its 128x64 pixel back light Liquid Crystal Display.

The Auto Fault Location key will move the cursor directly to the first event or fault, thus eliminating the need to visually interpret the wave form. When set in manual mode, the wave form may be visually scanned as on conventional TDRs. In both modes the user variable gain covering the range of default to 64 db's may be used to magnify small events identified on the waveform. The scan lock feature will allow the user to hold the trace for closer examination.

Designed for identifying and locating faults on all metallic cables with two or more insulated conductors. The TX4000 has impedance matched circuits for 25, 50, 75 and 100 ohms and with velocity of propergation settings from 1-99% (or the equivalent in feet or meters/micro second) will cover the range of power, data, communication and CCTV cables.

Housed in a rugged IP54 rated ABS enclosure and weighing only 350 grams (12 ounces), the TX4000 is suitable for outside use.



Ranges meters 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km
feet 23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 13120
Range Selection Manual range control
Accuracy 1% of selected range*
Resolution Approx 1% of range
Sensitivity Min 3 pixel return at 4km on 0,6mm , PE , TP
Velocity Factor Adjustable from 1% to 99%
Output Pulse 5 volts peak to peak. Into open circuit
Output Impedance Selectable 25, 50, 75 & 100 ohms
Output pulse Width 3 ns to 3 ms, Automatic with range
Scan Rate 2 scans / second or scan held (not on 3km/6km range)
Tone Generator 810 - 1100Hz
Battery Life 60 hours continuous scanning
Power Supply 6 volts 4 x 1.5 AA Alkaline cells
Power Down Selectable 1, 2, 3, 5 minutes or disabled
Back Lit Display 128 x 64 pixel
Voltage Detection 250 volts AC
Operating Temp -10º / 50ºC
Storage Temp -20º / 70ºC
Dimensions 165 x 90 x 37 (6.5 x 3.5 x 1.5 ins)
Weight 350 gms (12oz)
Safety IEC 61010-1
EN 60950
EMC BS/EN 61326-1
Water/Dust Proof IP54

TX4000Datasheet

TX4000 Manual